Welcome to Marinplus/Odelco!

Welcome to Marinplus!

Contact us at +46 8 718 03 00
This email address is being protected from spambots. You need JavaScript enabled to view it.

Print

TLA100

P/N: TLA100-01
Tank Level Adapter
Description

The TLA100 is used to adapt commercially available resistive tank senders to the NMEA 2000® network. This allows you to observe tank levels anywhere on the vessel where there are NMEA 2000® compatible displays such as the Maretron DSM150/DSM250.

nmea-2000-logo-productsThe TLA100 is compatible with both the American standard (240-30 ohm) and the European standard (10-180 ohm) resistive senders. In fact, the TLA100 can be calibrated for any resistance between 0 and 300 ohms.

Unlike most tank senders that only work with rectangular tanks, the TLA100 can be calibrated for irregular tank shapes so you know the true level of the tanks. You can also use the TLA100 with analog gauges at the same time as NMEA 2000® so you don’t have to give up existing analog gauges to enjoy the advantages of digitally networked information.

Features

  • NMEA 2000® Interface
  • Adapts American standard (240-30 ohm) resistive senders to NMEA 2000® Network
  • Adapts European standard (10-180 ohm)resistive senders to NMEA 2000® Network
  • Calibrated for any Resistance Range from 0 to 300 Ohms or 300 to 0 Ohms
  • Accommodates Irregularly Shaped Tankswith 16 Point Calibration
  • 16 Programmable Tank Types Including Fuel, Fresh Water, Waste Water, Live Well
  • Programmable Tank Number(s) Up to 16 per Tank Type
  • Programmable Tank Capacity
  • Works Alongside of Analog Gauges
  • Can be Used Standalone without Analog Gauges

Products

Part number Description
TLA100-01 Tank Level Adapter

Specifications

Parameter Value Comment
Accuracy +/-2% Does Not Include Inaccuracies of Analog Gauge or Sender
Resolution +/-1% Worst Case (Resolution Better at High Resistance Values)
Number of Tank Types 16 Fuel, Fresh Water, Waste Water, Live well, Oil, etc.
Number of Tanks per Tank Type 16 16 Tanks per Tank Type Numbered 0-15
American Standard Senders 240-30 ohms Standard Sender Types are User Selectable
European Standard Senders 10-180 ohms Standard Sender Types are User Selectable
Calibration Resistance Range 0-300 ohms Non-Standard Sender Calibration
Support for Irregularly Shaped Tanks Yes Can be Calibrated for any Shape Tank
Programmable Tank Capacity Yes Allows Displays to Calculate Amount Remaining
Analog Gauge Support Yes Can be Used With or Without Analog Gauges

Certifications

Standard Comment
NMEA 2000® Standard Level B+
Maritime Navigation and Radio Communication Equipment & Systems IEC 61162-3
Maritime Navigation and Radiocommunication Equipment & Systems IEC 60945
FCC and CE Mark Electromagnetic Compatibility

NMEA 2000® Parameter Group Numbers (PGNs)

Description PGN # PGN Name Default Rate
Periodic Data PGNs 127505 Fluid Level 0.4 Times/Second
Response to Request PGNs 126464
126996
126998
PGN List (Transmit and Receive)
Product Information
Configuration Information
N/A
Protocol PGNs 059392
059904
060928
065240
126208
ISO Acknowledge
ISO Request
ISO Address Claim
ISO Address Command
NMEA Request/Command/Acknowledge
 

Electrical

Parameter Value Comment
Operating Voltage 9 to 16 Volts DC Voltage
Power Consumption (Maximum) <100mA Maximum Current Drain
Load Equivalence Number (LEN) 2 NMEA 2000® Spec. (1LEN = 50 mA)
Reverse Battery Protection Yes Indefinitely
Load Dump Protection Yes Energy Rated per SAE J1113

Mechanical

Parameter Value Comment
Size 3.9” x 1.2” x 1.0” (99mm x 30mm x 25mm) Excluding NMEA 2000® Connector & Cable
Weight 9 oz. (255g)  
Mounting Any Orientation  

Environmental

Parameter Value
IEC 60945 Classification Exposed
Degree of Protection IP67
Operating Temperature -25°C to 55°C
Storage Temperature -40°C to 70°C
Relative Humidity 93%RH @40° per IEC60945-8.2
Vibration 2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7
Rain and Spray 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8
Solar Radiation Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
Corrosion (Salt Mist) 4 times 7 days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Electromagnetic Emission Conducted and Radiated Emission per IEC60945-9
Electromagnetic Immunity Conducted, Radiated, Supply, and ESD per IEC 60945-10
Safety Precautions Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12

Manuals

Download User Manuals

CONTACT US

Address: