Welcome to Marinplus/Odelco!

Welcome to Marinplus!

Contact us at +46 8 718 03 00
This email address is being protected from spambots. You need JavaScript enabled to view it.

Print

RIM100

P/N: RIM100-01
Run Indicator Module
Description

Maretron’s Run Indicator Module monitors both AC and DC electrical circuits and reports, over an NMEA 2000® network, whether or not the electrical circuit is energized and running. The RIM100 works equally as well for monitoring manually switched loads (e.g., running lights, anchor lights, or deck lights) as it does for automatically switched loads. Monitoring automatically switched loads (e.g., bilge pumps, engine exhaust/intake fans, and transfer pumps) via the RIM100 is especially useful because you know exactly when equipment is, or isn’t running.

nmea-2000-logo-productsFeatures

  • Monitors and reports the running statuses of six independently connected devices
  • Works with both AC and DC loads
  • Works with both automatically and manuallyswitched loads
  • Can indicate the status of a wide variety of loads
    • Bilge Pumps
    • Winches
    • Running Lights
    • Transfer Pumps
    • Exhaust/Intake Fans
    • Water in Fuel notification

Products

Part number Description
RIM100-01 Run Indicator Module
WIF-RK30880-E Water-In-Fuel Detector

Specifications

Parameter Type Comment
“ON” Voltage Range (DC) 9VDC to 240VDC  
“ON” Voltage Range (AC) 9VAC to 240VAC  RMS

Certifications

Standard Comment
NMEA 2000® Standard Level A
Maritime Navigation and Radio Communication Equipment & Systems IEC 61162-3
Maritime Navigation and Radiocommunication Equipment & Systems IEC 60945
FCC and CE Mark Electromagnetic Compatibility

NMEA 2000® Parameter Group Numbers (PGNs)

Description PGN # PGN Name Default Rate
Periodic Data PGNs 127501 Binary Switch Bank Status 1 Time/15 seconds and on switch change
Response to Request PGNs 126464
126996
126998
PGN List (Transmit and Receive)
Product Information
Configuration Information
N/A
Protocol PGNs 059392
059904
060928
065240
126208
ISO Acknowledge
ISO Request
ISO Address Claim
ISO Address Command
NMEA Request/Command/Acknowledge
N/A
Maretron Proprietary PGNs 128720 Configuration N/A

Electrical

Parameter Value Comment
Operating Voltage 9 to 32 Volts DC Voltage
Power Consumption (Maximum) 100mA NMEA 2000 Interface
Load Equivalence Number (LEN) 2 NMEA 2000® Spec. (1LEN = 50 mA)
Reverse Battery Protection Yes Indefinitely
Load Dump Protection Yes Energy Rated per SAE J1113

Mechanical

Parameter Value Comment
Size 3.50” x 4.20” x 2.03” (88.9mm x 106.7mm x 51.6mm) Including Flanges for Mounting
Weight 13 oz. (368.5 g)  

Environmental

Parameter Value
IEC 60945 Classification Exposed
Degree of Protection IP64
Operating Temperature -25°C to 55°C
Storage Temperature -40°C to 70°C
Relative Humidity 93%RH @40° per IEC60945-8.2
Vibration 2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7
Rain and Spray 12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8
Solar Radiation Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
Corrosion (Salt Mist) 4 times 7 days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Electromagnetic Emission Conducted and Radiated Emission per IEC60945-9
Electromagnetic Immunity Conducted, Radiated, Supply, and ESD per IEC 60945-10
Safety Precautions Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12

Manuals

Download User Manuals

CONTACT US

Address:
Marinplus AB/Odelco AB
Missionsvägen 77
SE-167 33 BROMMA
SWEDEN

Mail:
info@odelco.se
order@odelco.se
support@odelco.se

Phone:
+46 8 718 03 00

ABOUT US